HOME › Cardiac Care › Pulse MedSure Sirolimus Stent

Coronary Stent | Drug-Eluting Stent

Pulse MedSure Sirolimus Stent

Sirolimus-eluting cobalt chromium coronary stent with 59 µm struts and a hybrid design of open and closed cells. Open cells in the middle of the stent make it easier to reach and treat a side branch.

Sirolimus-Eluting 59 µm Struts Side-Branch Access
Get a Quote Contact Us Download Brochure

Key Features

Technical Specifications

Stent materialSurgical grade cobalt chromium (L605), laser cut from seamless tubing in a serpentine pattern
DrugSirolimus
PolymerBiodegradable, 100% resorbed in 6–7 weeks
Strut thickness59 µm
Stent architectureHybrid cell design (open and closed cells) with non-linear links
Stent recoilUnder 6%
ForeshorteningUnder 2%
Delivery systemRapid exchange (RX)
Usable length142 cm
Guidewire0.014 inch (0.36 mm); exit port 25 cm from the tip
Delivery balloonNylon, about 1.0 mm longer than the stent
MarkersRadiopaque gold (18K), proximal and distal
Nominal pressure9 atm
Rated burst pressure16 atm
Guiding catheter5 Fr (1.4 mm) compatible
Diameters2.25, 2.50, 2.75, 3.00, 3.50, 4.00, 4.50 mm
Lengths12, 14, 18, 22, 26, 30, 34, 38, 42, 46, 50, 54 mm
CertificationISO 13485:2016, CE (notified body 1035)

MedSure Sizes and Order Codes

MedSure comes in 7 diameters and 12 lengths, 74 sizes in all. Order codes follow the pattern MS + diameter + length (for example, MS30018 is 3.00 mm × 18 mm).

Length2.25 mm2.50 mm2.75 mm3.00 mm3.50 mm4.00 mm4.50 mm
12 mmMS22512MS25012MS27512MS30012MS35012MS40012MS45012
14 mmMS22514MS25014MS27514MS30014MS35014MS40014MS45014
18 mmMS22518MS25018MS27518MS30018MS35018MS40018MS45018
22 mmMS22522MS25022MS27522MS30022MS35022MS40022MS45022
26 mmMS22526MS25026MS27526MS30026MS35026MS40026MS45026
30 mmMS22530MS25030MS27530MS30030MS35030MS40030MS45030
34 mmMS22534MS25034MS27534MS30034MS35034MS40034MS45034
38 mmMS22538MS25038MS27538MS30038MS35038MS40038MS45038
42 mm—MS25042MS27542MS30042MS35042MS40042MS45042
46 mm—MS25046MS27546MS30046MS35046MS40046MS45046
50 mm——MS27550MS30050MS35050MS40050MS45050
54 mm——MS27554MS30054MS35054MS40054MS45054

— Not available.

MedSure Compliance Chart

Stent inner diameter (mm) at each inflation pressure. Green is the nominal pressure (9 atm); red is the rated burst pressure (16 atm). Do not inflate beyond the rated burst pressure.

Pressure (atm)2.25 mm2.50 mm2.75 mm3.00 mm3.50 mm4.00 mm4.50 mm
42.002.302.542.753.303.804.25
62.102.352.602.803.393.854.30
72.152.402.652.903.423.894.40
82.232.492.752.993.453.984.49
9 (nominal)2.252.512.783.023.484.004.52
102.282.542.803.043.514.024.55
112.302.592.863.103.624.124.58
122.322.622.893.143.664.164.60
132.352.652.923.183.704.204.65
142.392.672.953.203.744.244.68
152.412.702.983.223.784.274.72
16 (rated burst)2.432.723.013.263.804.304.75
172.452.753.043.303.824.324.78
182.472.793.083.353.864.364.81
202.482.813.123.403.894.404.86

Side-Branch Access With MedSure

When a narrowing sits where a side branch leaves the main artery (a bifurcation), the cardiologist often stents the main branch first, then opens the side branch through the stent struts. MedSure has open cells in its middle segment for this. The struts there can be widened with a semi-compliant or non-compliant balloon such as Glider SC or NC, and a second stent can be passed into the side branch.

Pulse Drug-Eluting Stents Compared

Pulse offers four drug-eluting stents. All treat coronary artery disease; they differ in the drug and the design.

DrugStrutsStands out for
EvroSureEverolimus (1.1 µg/mm²)59 µm, cobalt chromiumThin struts; polymer fully breaks down in 6–7 weeks
MedSureSirolimus59 µm, cobalt chromiumOpen cells in the mid segment for side-branch access
EveraEverolimus65 µm strut widthHigh stent retention on the balloon (dislodgement force over 5)
SirovaSirolimus65 µm strut widthFlexible cells and S-link connectors for twisted arteries

What to Check Before Adding a Stent to Your Cath Lab

The Pulse Cath Lab Consumables Range

Pulse supplies the main single-use items for a cath lab, so one supplier answers for supply and documents.

Pulse productWhat it does
AcuSafe Micro-Access Introducer KitsSmall-needle first puncture of the artery or vein, then a sheath
AcuSafe Introducer KitsSheath and dilator that keep the vessel open for catheters and wires
GuideX GuidewiresWires that guide sheaths and catheters into place and support exchanges
Optima ManifoldsControl contrast injection, flushing and pressure monitoring
Glider PTCA balloons (SC, NC, CTO)Open the narrowed artery before a stent, and expand the stent fully after
Optima Inflation Device KitInflates the balloon to a measured pressure to open the artery and expand the stent
Evera, Sirova, EvroSure and MedSure (this page) stentsDrug-eluting stents that hold the opened artery open
Mamba drug-coated balloonDelivers sirolimus to the artery wall without leaving a stent behind
AcuSafe Blunt NeedleControlled access for percutaneous drainage (interventional radiology)

Share the sizes you use and your monthly volume, and request a quote. Ask for the brochure, IFU and certificates with your quote.

Complete the setup

You May Also Need

Buying guides

Related Guides

← Back to Cardiac Care

Got Questions?

MedSure Sirolimus Stent FAQs

MedSure is a drug-eluting coronary stent used in angioplasty to hold a narrowed or blocked heart artery open. It releases sirolimus to help stop the artery from narrowing again.

MedSure has open cells in the middle of the stent. A balloon can be passed through them to open a side branch, and a second stent can be placed there if needed.

Diameters of 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 and 4.50 mm, and lengths from 12 mm to 54 mm. The 2.25 mm size goes up to 38 mm long and the 2.50 mm size up to 46 mm.

The nominal pressure is 9 atm and the rated burst pressure is 16 atm. The compliance chart on this page shows the stent diameter at each pressure.

Both release sirolimus. MedSure has thinner 59 µm cobalt chromium struts and open mid-segment cells for side-branch access; Sirova has 65 µm struts and S-link connectors for flexibility.

The MedSure brochure lists ISO 13485:2016 and CE marking (notified body 1035). Ask the Pulse team for the current CDSCO licence and certificates.

Drug-eluting stent prices in India are capped by the NPPA. Message Pulse on WhatsApp at +91 90711 01108 with your sizes and monthly volume, or download the brochure on this page.

Welcome to Pulse, How may I help you?
Hi!👋
Pulse AI Assistant